How to adjust a kiturami diesel boiler. High efficiency and simple design - this is the Kiturami diesel boiler

Kiturami Turbo boiler maintenance

The technical condition of the Kiturami Turbo 13R/17R diesel boiler depends on the impact external environment into its individual nodes, such as:

Fuel path;

Combustion products exit path;

Heating circuit;

Hot water circuit;

Electrical elements operating on 220V voltage.

In practice, the intensity of the influence of the external environment on each of the listed components and elements of the boiler varies. In this case, the degree of influence of the external environment depends on the correct implementation of all instructions in this passport.

The list of the influence of the external environment on the components and elements of the boiler determines the order preventive measures to eliminate them.

Impact of the external environment on Kiturami Turbo 13R/17R boiler systems

Fuel path

Diesel fuel containing:

Mud inclusions;

Precipitates that form when adding additives

A fuel tank is like a container that:

Accumulates dirt coming with fuel;

It is a constant supplier of rust if the inner walls of the steel container do not have a special coating.

Combustion products exit path

Soot, which is formed during incomplete combustion of the fuel mixture.

Condensation of water vapor, which is formed as a result of combustion of the fuel mixture.

Aggressive elements contained in fuel or air, and dissolved in water formed during condensation of vapors.

Heating circuit

Precipitates coming from the heating system, which are formed when the ferrous metal of the heating system elements interacts with the coolant, as an active solvent.

Chemical elements contained in non-freezing liquid.

Slag remaining in the heating system after installation.

Hot water circuit

Chemical elements dissolved in water and capable of precipitating.

Elements in the form of suspensions, slag, rust, etc., which are contained in the water supplied to a heated building.

Electrical elements

Deviations from standard power supply values ​​operating at 220V voltage

Humid environment in the room where the Kiturami Turbo boiler is installed.

Aggressive substances of various origins that, through a humid environment, affect detachable connections.

Preventative cleaning of the boiler must be done at least 1-2 times a year.

The interval between preventive cleanings must be adjusted if operating conditions differ from the instructions in this passport.

Preventive measures include cleaning or replacing fuel path elements:

- fuel filter(replacement only);

Fuel tank (cleaning);

Fuel pump (cleaning, replacement);

Hydraulics of the burner air damper (cleaning, replacement of individual elements);

Liquid fuel injector (replacement only);

Pipelines supplying fuel to the unit (cleaning);

Burner pipelines (cleaning, replacement).

Preventive measures include cleaning or replacing elements in the exhaust path of combustion products:

Cleaning the surfaces of the boiler heat exchanger;

Replacing turbulators,

Replacing the filter (in floor-standing units with a thermal power of up to 30,000 kcal/hour).

Preventive measures determine the cleaning of the combustion products exit path from the Kiturami Turbo boiler:

Chimney pipe cleaning;

Cleaning the chimney duct pocket;

Cleaning the chimney duct.

Preventive cleaning of the heating circuit of the unit includes the following operations:

Chemical washing;

Cleaning the mesh filter installed on the return pipeline in front of the boiler;

Filtration or replacement of low-quality coolant.

Preventive cleaning of the hot water supply circuit of the Kiturami Turbo 17R boiler includes the following operations:

Chemical washing;

Cleaning or replacing treatment units, filters, etc.

Preventative work to inspect elements electrical equipment boiler:

External inspection of all wires (mechanical damage, exposure to aggressive environments, etc.);

Inspection of all detachable connections(quality of contacts, mechanical damage, exposure to aggressive environments, etc.);

Inspection of electrical equipment (quality of connected grounding, presence of dust, mechanical damage, exposure to aggressive environments, etc.).

Checking all sensors of the unit (external inspection, presence of dust, dirt, exposure to an aggressive environment on the working surfaces of the sensors, physical wear, etc.).

Checking the operation of the Kiturami Turbo boiler after maintenance

Checking the quality of operation of the Kiturami Turbo 13R/17R boiler is carried out using the following instruments:

Pressure gauges to determine the pressure at the inlet and outlet of the heating circuit and hot water supply circuit, and compare measurements before and after maintenance work;

Thermometers for determining the temperature at the inlet and outlet of the heating circuit and hot water supply circuit, under various boiler operating modes;

Pressure gauge for determining the pressure of liquid fuel supplied to the injector;

Thermometers for determining indoor air temperature and exhaust gas temperature;

Gas analyzer, to determine the content in quantitative measurement of emissions contained in combustion products, and to determine the efficiency of the burner during fuel combustion;

A device for determining the soot number in combustion products.

Adjusting the burner of the Kiturami Turbo boiler

Adjusting the air supply to the burner

Burner adjustment is performed during commissioning or during maintenance work.

The air supply to the boiler combustion chamber is adjusted using an air damper (see Fig. 13).

When adjusting the air damper, the adjustment criterion is the color of the flame, and:

If the flame is black-red, you need to increase the air supply;

If the flame is bright white, reduce the air supply;

When the flame is yellow-red, the pre-setting is complete.

Checking the completeness of fuel combustion and the operation of the burner with rated thermal power is performed with a gas analyzer and a device for determining the soot number.

Fig. 13. Burner for diesel boiler Kiturami Turbo 13R/17R

Adjusting the ignition electrodes

Adjustment of the ignition electrodes determines the quality of ignition of the fuel mixture.

Adjustment of ignition electrodes includes:

Distances between electrodes 3.5+0.3 mm;

The distances between the electrodes and the center of the nozzle are 6.5 -0.1 mm;

The distances between the electrodes and the working plane of the nozzle are 5.0+0.1 mm.

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

Proterm Panther Proterm Skat

Kiturami boilers are distinguished by their compactness, minimalism in detail and maximum efficiency. And although the assembly of components and design development within one plant provide high quality products, this does not exclude the fact that over time, scheduled maintenance and redecorating she won't need it.

What are the differences between Kiturami heating boilers and what can cause them to break down?

The species diversity of Kiturami boilers affects the troubleshooting technology, so consideration of the types of their energy supply and design features is very important.

According to the type of fuel used, Kiturami boilers are divided into:

  • diesel (Turbo, KSO series);
  • gas (Twin Alpha, World Plus, KS);
  • biofuels (KRM).

In addition, the company also produces solid fuel (KF), condensing heating boilers that can operate on combined fuels. Regardless of the type of device, they all have similar equipment, which includes 5 levels:

  • an air system, which includes a chimney and inlet;
  • hydraulics, whose main function is to perform heat exchange of the coolant;
  • automatic control, with sensors and regulators;
  • the fuel system, through which the fuel enters the injector and is transferred by the pump;
  • electrical component.

All these levels interact with each other and provide the technical component (passport) of the device, so they must work uninterruptedly. That is why, if problems are detected, repair of Kiturami boilers must be carried out comprehensively. After all, even if the gear panel sensor shows a system failure, it will not indicate the real reason for the deviations in operation: be it a lack of grounding or a simple lack of fuel.

The main causes of problems include:

  • violation of operating rules;
  • incorrect installation;
  • depreciation of equipment;
  • untimely service.

Problems with diesel boilers

The main difference between diesel boilers produced by Kiturami is their high efficiency, which is achieved through protection and heat transfer systems. These systems are enabled to operate by a special boiler device, which looks like this:

  • 1 element - a standard heating device, which contains a heat exchanger, burner, chimney and control panel;
  • 2nd element - attached, is a container with fuel to which a pump is connected; it distills diesel fuel into the combustion chamber, where it mixes with oxygen, releases heat and heats the heat exchanger.

In addition, such a boiler can operate on two types of fuel if a combination burner is installed. But at the same time, to ensure maximum efficiency of the device, the angle of the nozzles must be set at a special angle, which can only be done by specialists. Otherwise, if there is the slightest error in installation, the device will fail and repair will be necessary.

Possible causes of breakdowns:

  • use of low-quality fuel, which can freeze and contain small particles of debris;
  • incorrect burner angle setting;
  • errors when tying the unit.

In addition, the cause of a breakdown can be the use of a fuel container that does not have a pipe for draining diesel fuel, waste liquid and settled dirt.

Common signs of breakdown

What indicates a breakdown in the boiler:

  • the appearance of noise and vibration when starting the device;
  • there is a visible accumulation of debris on filters, fuel lines, hoses;
  • an emergency shutdown of the device occurs;
  • flashing sensors on the control panel are triggered and an error is reported;
  • in the absence of power supply, the boiler continues to operate;
  • accumulation of a large amount of soot in the chimney;
  • problems with burner ignition.

How to prevent failure

In order not to make expensive repairs, resorting to the help of specialists, you must adhere to following rules for the operation of Kiturami boilers:

  • When filling the tank with fuel, the device must be turned off;
  • The device can be started after refueling only after 30 minutes, when the fuel has settled;
  • replace the filter every 3-6 months, depending on the intensity of use;
  • connect a UPS to the boiler so that the device does not fail due to power surges;
  • do not exceed the temperature conditions specified in the instructions (the boiler can be heated to no more than 85 degrees Celsius);
  • It is better to purchase a tank for a fuel container with a fixed package, thanks to which it will be transferred to the boiler upper layer diesel fuel, and the lower one, with particles and sediments, will remain at the bottom.

You can learn how to maintain the cleanliness and efficiency of Kiturami boilers from the video below.

The importance of scheduled replacement of elements and preventive cleaning of the device

If preventive maintenance is carried out in a timely manner, this will allow:

  • avoid minor problems during equipment operation;
  • extend the service life of the unit;
  • configure the automation correctly;
  • bring the technical data of the equipment into compliance with its passport data.

Only professionals should be trusted to clean Kiturami boilers. Self-repair and replacement of parts, which are most often purchased at a low cost, are of poor quality and have manufacturing defects, lead to a violation of the environmentally significant factors of the boiler: they contribute to the release of carbon monoxide, the spread of the smell of diesel fuel, etc.

Exist special services for the maintenance of devices of this brand, which guarantee high-quality cleaning of the device and ensure the replacement of worn parts with original components. Their services also include round-the-clock monitoring of boiler sensors and notification of its owner in case it is necessary to carry out urgent equipment repairs. The contract with such centers is concluded for a year and is negotiated during the process of purchasing a boiler in a company store or from an official dealer.

In contact with

Kiturami boilers from a Korean company have many advantages, which allows them to be used for arranging various types heating. These types of devices are quite practical and popular among users as they are very reliable.

You can organize diesel heating of a country house yourself, but the best option will entrust the performance of such work to specialists who know their business. Before purchasing these types of boilers, you must first study everything specifications and select it under certain conditions.

We ensure optimal performance

Such boilers operate very efficiently, but the quality of their work depends on correct settings some settings during installation.

When installing this structure, the following should be taken into account:

  • The quality of the fuel used. In order to ensure optimal movement of diesel fuel during connection, a special burner is installed that will heat the solution in winter.
  • Correct placement of burner nozzles. Such work can be carried out using special equipment.
  • Correct installation of the boiler. The design of the product provides for the presence of various outputs for connection, which must be connected correctly, and also ensure insulation of the entire chimney system.

The developers provide a large number of options that can be customized to suit your personal needs.

The main ones are:

  • "Premises." This setting allows you to adjust the temperature in the room, which is done using a specific regulator.
  • "Dream". The corresponding regulator on the panel allows you to limit energy consumption during sleep, which significantly reduces fuel consumption and after a certain period of time the general heating of the room is turned on.
  • "Bath". This mode allows you to use hot water over a period of time. This function is relevant if there are a large number of people in the family and the water simply does not have time to heat up as usual.
  • By turning the control to the Away position, you can significantly reduce fuel consumption.

Since there are a very large number of Kiturami boilers on the market, tuning and installing each of them is an individual process. To perform such work very efficiently high level, you should entrust their implementation to specialists who know how to do it.

Kiturami STS boiler (Kiturami) in the video:

Please tell me what is the difference between diesel Kiturami boilers turbo, stso and hi fin? Apparently, hi fin is the most new model, but at the same time its efficiency is lower than that of turbo by almost 6%. Where is the innovation here? As I understand it, the only difference with stso is in the supply air pipe. Correct me if anything.

Turbo is a steel heat exchanger, sts is stainless steel, the shape of the heat exchanger channels is different, there are pictures in the topic, sts are vertical channels and are easier to clean, sts has an inlet pipe. Hi-fi comes in both turbo and STS, turbo is again steel, STS is stainless steel, the essence of hi-fi is some kind of corrugated pipes that provide increased heat removal.

Kiturami Turbo 13 has turned off and is showing error 95. What does this error mean?

Error 95 means low water level in the boiler. The coolant should be added, the pressure will rise to an operating value of 1.5 atm, and the unit will start. If this is not actually the case, then you should check the serviceability of the water level sensor. You also need to check the system for leaks and air pockets.

The Kiturami boiler heats up to 40 and stops with error 01. What should we do?

The error indicates the absence or insufficient traction. Either the boiler is clogged with soot, or there is no flow of fresh air into the boiler room. The burner settings may also have gone wrong. the following parameters: by exhaust gases, by temperature, efficiency and other indicators.

We have a Kiturami turbo 17r boiler. original remote control. During operation, several questions arose: The air temperature sensor in the remote control increases the temperature by 2 degrees. I specifically hung a regular thermometer next to the remote control. The thermometer shows 23, the remote shows 25. Is this kind of overestimation normal or not? I read the user manual, but did not find the answer: when the boiler operates based on the coolant temperature, what is the lower coolant temperature at which the unit switches on? Is this a specific temperature, or is there a temperature range built into the control board? I mean, for example, it’s a specific +45, or it’s, for example, a difference of 20 degrees depending on the set upper temperature. Help us understand what will turn on the boiler frequently and what will not. Yesterday I was puzzled - the evening followed him. It now operates according to coolant temperature, because it heats two two-level garages of varying degrees of insulation (total heated area is approximately 170 sq.m.). He himself works in 3/10 mode. In the sense that it works for 3 minutes, it costs 10 minutes. The coolant is currently set to 65. Is mode 3/10 too frequent or normal? Now the practical consumption is 11-12 liters per day. Is this a lot or is it normal for such a model and such a heating area?

The remote control can be calibrated, the settings allow you to do this. What kind of remote control do you have? Although the accuracy of the thermometer is also questionable, if this confuses you, it can be corrected.

The Kiturami boiler is working, but due to the fact that the voltage is low, and the tank for diesel fuel is buried in the ground near the boiler room, an additional KR-6 pump is installed, apparently it does not have enough voltage to supply the diesel fuel, and the original pump also cannot cope . Therefore, once, or even twice a day, the unit stops due to error 01, there is air in the filter. I pump up the diesel fuel with the same KR-6, but connected directly to the network, I bleed the air from the filter and it starts and works. I checked the line for air leaks completely, it doesn’t suck anywhere. Everything is fine with the voltage in the network, there is a stabilizer for the whole house, the network is 223 volts, the voltage of 160-170 volts comes directly to the Kiturami R13 fuel pump. Something broke in the boiler itself, so I’m asking - maybe someone has encountered such a problem?

I have a diesel Kiturami STS-17 - it gave error 01 without a stabilizer. We connected the stabilizer separately to the sockets in the boiler room. It started working fine. During a power outage, I was using the generator, periodically it gave an error of 0, the input was 230, but when you load the generator, it works more smoothly. Also, if I have input voltage

160, 170-200, I turn off everything I can - light bulbs, boiler, kettle. Otherwise, the stabilizer will start to turn off and, if it is 160 for a long time, then it does not output 220V, but 200, and there will be an error.

Please suggest a solution to the problem. The Kiturami R17 worked flawlessly for 2 months from the moment of purchase. At the moment, it keeps writing error 01. The diesel fuel is coming in, the filter has been replaced, the flame sensor has been cleaned. Where else can I look to solve the problem?

Look for air leaks in the fuel line.

Kiturami STSO-25 and STSO-30 are the same boiler. The basic one is naturally 30th. That is, if we want to get 25 out of 30, we need to reduce the amount of fuel supplied. How? Well, naturally, with a nozzle of a smaller flow area. The liquid fuel flow produced by the nozzle must be adapted to the power at which the burner is installed. But this is one way. The second is by changing the pressure on the injector, adjusting the fuel pump. And this way we change the fuel consumption, and, consequently, the heat generation power. We already have an injector, 0.75. The power that the unit should produce is also known, it is 29.1 kW. Well, let's estimate what power the boiler will actually reach at 8, 9 and 10 bars. At a pressure of 8 bar and a nozzle of 0.75, the fuel consumption is 2.55 kg/h, which corresponds to a power of 30.2 kW. At a pressure of 9 bar and an injector of 0.75, the fuel consumption is 2.70 kg/h, which corresponds to a power of 32.0 kW. At a pressure of 10 bar and a nozzle of 0.75, the fuel consumption is 2.85 kg/h, which corresponds to a power of 33.8 kW.

The Kiturami Turbo diesel boiler constantly operates in this mode: it heats up for 10-15 minutes and goes into error E01. Only after a restart it turns on, and soon the same error occurs. It's almost new. What could have happened to him?

The flame detection system does not work, and this is a common occurrence for oil boilers when the diesel burner was not adjusted during installation. The fact is that the factory settings usually do not correspond to operating conditions. Individual adjustment of the burner with a gas analyzer is required. This device allows you to see the combustion picture in many parameters and configure it correctly, taking into account the given fuel and air flow in a given boiler room.

The boiler began to show an error: something is connected with the ash pan, and the red emergency lamp is on. What needs to be done to fix this?

An inspection and troubleshooting is required. Preventative work before the start of the next heating season required by the boiler annually. In your case, the firebox is 100% clogged, and the chimney also needs to be inspected. A firebox heavily contaminated with soot can be cleaned by you yourself.

The Kiturami boiler has been working perfectly for several years without any intervention.

What needs to be done to ensure that it continues to work no worse? To maintain boiler equipment in good working order, annual. This concept includes cleaning the inside of the unit, mandatory replacement of the nozzle and filter, checking the automation and condition of the chimney.

The Kiturami 17 diesel boiler has stopped, error 01 is flashing. I’m thinking of cleaning everything myself. What should you do first?

First of all, you need to check the condition of the firebox and chimney to see if they are clogged with soot. You can do this yourself. Then check the cleanliness of the injector and the serviceability of the fuel pump. At least once a year you need to clean the outside of the heat exchanger.

The Kiturami Turbo 30R liquid fuel boiler is new, but it works very poorly, often goes out, lights up for a few minutes and turns off again. What about the factory settings of the burner?

Factory settings correspond to the factory operating conditions of the boiler. At your home they may be completely different. It is necessary to configure the burner with the following characteristics: condition of the chimney, gas pressure, presence of air flow into the room. The cleanliness of the firebox is important, and it can clog in just a week if the fuel is of poor quality.

The unit is new, it has only been working for 2 months, and suddenly it stopped. The indicator indicates that the burner is working, but it does not work. It doesn't show any error. What is the reason?

Perhaps the boiler automation is set to a certain operating mode - for example, to a time-limited mode when the burner does not turn on. This is especially true for boilers with an outside temperature sensor, when the boiler goes into summer mode

. In this case, the indication remains. If there were problems with the burner or the flame, an error code would definitely appear.

The Kiturami diesel boiler suddenly puffed out when ignited, white smoke began to appear, and it no longer turns on. Recently we cleaned the injector from carbon deposits. What's wrong with the device?

Cleaning the nozzle is not enough for the boiler to operate correctly. Diesel boilers must undergo a preventive inspection at least once a year, including setting up the burner with a gas analyzer. It is impossible to adjust the burner without the device. At the same time, carbon deposits 2.5 mm thick reduce the efficiency of the boiler by 25%, and this is excess fuel wasted.

The Turbo 21R boiler consumes an average of 270 liters of fuel per month, heating 100 sq. m area. I was told that this is a lot. How to reduce consumption?

The Kiturami gas boiler does not turn on and shows error 01. What can you do yourself?

The device is clogged with soot, there is no traction for normal starting. You definitely need to clean either the burner or the firebox. Then the burner must be adjusted with a gas analyzer. You can clean the firebox from soot yourself: this is a mechanical job and does not require special skills. After this, you can adjust the burner.

The Kiturami 17 boiler unit does not turn on the fan, and a lot of soot has burned up. Do you resolve such issues?

Cleaning the firebox from soot is a very dirty and labor-intensive job, and therefore quite expensive. Therefore, we recommend doing it yourself.

Regarding the fan, you need to look at whether it has burned out and requires replacement or whether a system error has occurred in the automation. New condensing gas apparatus

does not turn on, error 02 appears on the display. How can I fix this?

Your boiler has an emergency shutdown due to an incorrect flame sensor signal. Try checking phase-zero and grounding on the boiler, check the cleanliness of the sensor. IN gas boiler

Kiturami water pressure is off the charts, showing 10-12 bar in the DHW circuit. Attempts to fix it did not lead to anything. What can be done? Such high pressure readings mean that either the sensor has failed or there is something wrong with the water influx. Possibly not installed correctly.

expansion tank

The Kiturami 17 boiler has stopped and the display shows error E 96. What to do in this case?

The error code indicates that the boiler heat exchanger has overheated, causing the thermal fuse to blow out. You can restore it yourself.

Look at the diagram for the location of the boiler water temperature sensor. There should be a fault suppression button in that area; after pressing the button, the boiler will start.

The device turns on for 15 seconds and goes back into standby mode; it does not accept commands from the remote control. Maybe you can recommend something?

The dirt filter in front of the boiler may be clogged. Or the condensate collector is full. You can clean the filter and drain the condensate at the bottom of the heat exchanger.

The Kiturami unit does not start, it shows error code 95. The water pressure seems to be normal - 1.2. What's wrong with the boiler?

Judging by the error code, there is a lack of water in the system. Normal pressure should be 1.5 bar. Add water and bring the pressure to this level. If after this the device does not turn on, it means that the minimum pressure sensor has failed.

The boiler (wall-mounted gas) Kiturami Twin Alpa gives error 95, there is water, when turned on it does not react at all, quiet clicks and that’s it. What is the reason?

The boiler must have a water pressure of 1 atm. Check the contacts on the coolant level sensor.

The STSO 30 gas boiler, in intensive heating mode ("tap" button), in addition to the water in the shower, very heats up the coolant in the heating system. It seems to me that this should not be the case with a 2-circuit boiler. Tell me what can be done?

We recommend installing it on the return pipeline after the mud trap, before the pump. check valve. Its resistance will prevent self-circulation through the heating system. With hot water supply, the volume of heated water will increase.

Problem with gas boiler kiturami twin alpha-16. We turned off the lights and after turning on the lights (there is a voltage stabilizer), the boiler began to show error 95, a pressure test was carried out on the system - there was no air in the system.

It gives error 95, the pressure is normal, it turns on and turns off immediately. How to fix this?

The water control sensor in the boiler may have failed. You need to check the sensor, if it is faulty, replace it. The control board may also be faulty.

I have a Kiturami World 2000 HI DELUXE-13 C. Water flows from the expansion tank all the time. They put a hose in - it goes into the sink. Previously, the expansion tank was not filled like this. What could be the reason? Perhaps they didn’t add it to the expansion tank in time air pressure

There was a problem when starting the kiturami World 5000 13r boiler, error (Er 01). The gas valve of the boiler does not work, the inlet pressure is 28 mbar, the background pressure at the outlet is 2 mbar. The overheating sensor is working, as is the photosensor.

Please explain the algorithm for turning on the block? How can I fix this problem myself?

Initially, it is necessary to check the supplied supply voltage and the absence of voltage to grounding. When starting, the fan turns on first, then voltage is supplied to the ignition electrodes, the next stage is voltage is supplied to the gas valve (200 Volts constant).

The regulators on the control unit work in reverse, clockwise reducing the voltage supply to the gas valve coil. When starting, cover the flame control sensor with your hand, otherwise there may be a false alarm and blocking of operation.

The Kiturami gas boiler stopped in operation due to error 95, that is, lack of water. But the water is okay. I replaced the sensor, but the error continues to appear. What could it be?

Your boiler has an emergency shutdown due to an incorrect flame sensor signal. Try checking phase-zero and grounding on the boiler, check the cleanliness of the sensor. In such a situation, either a damaged sensor or low water pressure is to blame. If the sensor was changed, then that is not the reason. Perhaps the malfunction can be easily fixed, for example, by replenishing the system with water to the required level. Try cleaning clogged contacts. But if the board burns out, it will have to be replaced. The Kiturami gas boiler requires servicing. What work needs to be done? Maintenance includes following works : cleaning and adjustment gas burner

, setting and adjusting automation, checking seals and

shut-off valves

, testing mechanisms. All sensors and filters are checked and replacements are made if necessary.

Tell me, does the Kiturami boiler measure the temperature using water or only ambient air? Until the room gets colder, it does not turn on to heat itself. This is right?

A Kiturami gas boiler has been installed. It works well for heating, and when heating water it supplies water continuously until it starts to overflow from above. If the DHW circuit is not turned on, it is still there warm water low pressure. What is the reason?

Typically, the DHW circuit and the heating system operate independently. In your case, there is a breakdown of the secondary heat exchanger when coolant flows from high pressure in small. That is, the systems are connected, and warm water with a closed DHW circuit is water from the heating system. IN in this case The boiler is not repaired, since the heat exchangers are assembled at the factory. Or broken
the hydraulics of the unit, or electrochemical reactions in the system; factory defects are also possible.

The Kiturami world boiler is malfunctioning and stops periodically. I clean the flame sensor and the unit works fine for a while, but soon the same thing happens again. He also began to smoke heavily. Maybe the problem is that the chimney is short, and it needs to be lengthened?

Your boiler needs a burner adjustment. If necessary, the nozzle must be replaced. Before this, the firebox is pre-cleaned of soot.

This procedure is mandatory at least once a year. Most likely, the increased soot is due to a clogged firebox and an unregulated burner. After adjustment, the burner operates much more efficiently and economically in terms of fuel consumption.

After a power outage, the Kiturami-2000 gas boiler went into error: error codes 96 and 02 flash alternately. Restarting does not change anything. What could have happened? It is obvious that the errors arose under the influence external forces

and do not correspond to either overheating of the water in the apparatus or a malfunction in the flame detection system. The constant display of these codes on the display indicates that the most likely cause of the violation is a burnt out electronic board.

Malfunction of the Kiturami Twin Alpha 13 boiler. It does not work and shows error 95, although there is enough water in the system. What else could be the reason for such an error?

If we rule out a malfunction of the water level sensor in the boiler, then we need to check the following factors: the gas valve is clogged, and therefore there is no gas supply.

The error means that there is no combustion process due to the flame control sensor not detecting the flame. You can do the following: remove the sensor and carefully clean it with a clean cloth to remove any dust or soot.

Then return the sensor to its place. This sensor can be found on the burner.

A Twin Alpha 16 kW wall-mounted boiler was installed. About once a month error 07 pops up. Can the device restart itself if the temperature drops below the set temperature?

Error code 07 – problems with smoke removal, not with the set temperature. It is necessary to check the fan impeller, the main heat exchanger for clogging factors, and the smoke exhaust duct itself. The world-5000 gas boiler is in operation. Stopped turning on after

summer downtime , when opening a hot water tap. Otherwise it functions normally. Please tell me the reason. Thank you. Check the inlet flow sensor

cold water . There is a turbine inside the plastic tube; when clogged, it stops rotating and the sensor does not work. The Kiturami 5000 boiler recently began to malfunction (after 5 years of operation). Everything that can be changed has been changed. It seemed to work fine, but after 2 weeks

normal operation

The pressure began to drop sharply, dropping to zero overnight. You dial the water up to 1.5 - it works fine. What could be wrong?

Most likely there is a leak in the heating system. Check the fill valve. Also check the operation of the expansion tank inside the device and the additional expansion tank on the heating system.

World 3000 30r boiler installed. Recently it started turning on with noise (pop, detonation). I changed the fan speed, but it didn't help. There is a digital pressure gauge. Where can I find out the static and dynamic pressure for 35KW model VK-8105C gas valve to check its operation,

The Kiturami boiler is malfunctioning, error 01 is flashing. Restarted many times, does not help. Please help me solve the problem.

The circulation pump burned out, replaced it with a new one. The world 5000 boiler started working at first, worked for several hours, and raised the temperature in the apartment by several degrees. I decided to check the “shower” mode - the water was cold. I restarted and then the unit began to hum (ignite) for a few seconds and went out. And this is always the case - 3 attempts to set fire and it gives error 01. The gas is on, the chimneys are not clogged, it is connected through a stabilizer (there are no other devices). I noticed something like this yesterday. I turn on the device. The fan turns on, the first attempt to ignite the burner, a couple of seconds, reset. Second attempt, I remove the front cover from the device and the burner lights up.

An icon appears on the remote control in the upper right corner (candle) and the unit starts working. And only this way, with the cover removed. But the heating is somehow poor; through the viewing window you can see that not all the burners are burning, but only a few on the left.

There can be many options: 1) the photocell is faulty, 2) the gas valve is faulty, etc. We recommend calling a specialist.

Gas boiler Kiturami twin alpha 13. Installation in the house, from the very beginning there was a problem with noise when starting, when heating only for the shower, there is no such problem, when heating for heating it rattles loudly, the water was drained from the heating, the adjustment was carried out by a service technician, what should I do?

The wall-mounted boiler Twin Alpha 16 is in operation. This year we installed water and it is not clear how the SHOWER function works. How to set it up step by step and tell me whether the SHOWER emblem should be displayed in the Presence mode on the display. How to find out whether the SHOWER mode has been turned on/off.

All data is in the boiler passport. Read your passport carefully. I want to put the Twin Alpha 25 boiler into operation. I bought it recently and am about to install it. The instructions say that you can connect and natural gas

, and liquefied gas. Liquefied gas, as I understand it, is gas from a cylinder, propane. Is it possible to immediately connect propane or is there something that needs to be changed?

It is necessary to reconfigure, replace the manifold with injectors and then configure the device again.

Please tell me, on the double-circuit wall-mounted gas boiler Kiturami WorldPlus-30 (without r) with the CTR-5700 Plus control panel, is the temperature set according to the coolant (i.e., according to the batteries)? I can’t display it in any way. How can I do it, can I put a different remote control? Otherwise there are inconveniences at room temperature. I want the batteries to always be warm.

I have a Kiturami gas boiler. I wanted to know if I need a red expansion tank. The operating instructions in the picture do not indicate the diagrams, but the seller said that it needs to be installed.

An additional expansion tank is required for the heating system.

Kiturami 5000 boiler, three-way valve leaked. I ordered it, time passed, I installed a new one, it stopped leaking. But upon startup, the pressure gauge was at zero, and an emergency discharge of water occurred. I removed the pressure gauge because... the device stood idle all summer, and it turned out that the entrance was simply clogged. I cleaned it with a needle, installed it, and the pressure immediately began to build up. But after 10-15 seconds.

Loud knocking starts and error 96 is displayed. Tell me what the problem could be now, I think all the troubles are due to the fact that the boiler has not been working for a long time. What can be done? Today, after trying to turn it on (unsuccessfully), I tried the circulation pump, it was very hot. Can it burn out if water dripping from the three-way valve gets on it?

Yes, most likely the circulation pump is faulty. Perhaps the thermal relay inside the pump is triggered; the pump sometimes works, sometimes it doesn’t.

The kiturami world 5000 boiler is malfunctioning. The three-way valve has recently leaked. I ordered it and replaced it (nothing complicated). But the water does not fill up, up to 1.5 bar the water fills up and is immediately discharged from below, what can be done?

Most likely, the pressure gauge or safety relief valve is faulty.

Kiturami error 01. What could be the reasons?

Error code 01 - no ignition. Most likely, the flame sensor needs to be replaced or the settings are incorrect.

Wall-mounted boiler world 5000 25r. Apparently the fan burned out during a thunderstorm (I determined the cause by the characteristic smell and by disassembling it; the circuit board inside the fan was charred). I bought a new fan and installed it myself, since there is nothing complicated about it (three screws and a plug). Immediately after plugging the plug into the socket, the fan began spinning at maximum speed.

Moreover, the device was not turned on from the remote control. Turned it on, the remote control shows errors 02, 07 alternately. The boiler does not try to ignite, the fan spins constantly, and turns off only by unplugging the plug from the socket. What could be the reason? There are suspicions that the brains were burned together with the fan. How to calculate a malfunction?

Most likely, the control unit has failed (burned out). Replacement required.

Boiler kiturami 2000 deluxe 30r when starting there is a popping sound from the suction pipe

The unit needs to be tuned up and most likely maintenance needs to be done.

The Kiturami Twin alpha 20 boiler is malfunctioning, very often it gives error 07. What could be the reason, the device has been in operation for 1.5 years.

Error code 07 – incorrect operation fan There may be several options: 1) the fan impeller is clogged, 2) the main heat exchanger (plates) is clogged from the outside, 3) problems with the chimney, 4) the voltage in the network is not normal, etc.

The World boiler displays error 01, what options do you recommend for fixing it?

It is necessary to check the ignition electrodes and gas line.

A Kiturami 5000 boiler was installed. It has been in operation for 5 years. Several months ago there were isolated cases when it turned off and showed Er 06. After a restart, it started working normally. And now, when heating the water, it suddenly turns off, off. / on does not help - again Er 06. Tell me, what could this be connected with?

Error code Er 06 - incorrect fan operation. The fan needs either maintenance or replacement.

Kiturami WORLD 3000 20-30R. First, error 01 - I cleaned the electrode (flame) - it went away and started to start. But it does not work smoothly, in one mode. It doesn't reach full capacity. Accordingly, when the heating is turned off, in shower mode, the water does not warm up properly. Tell me, please, what to do?

Most likely the device needs to be configured and adjusted.

The fan has failed. Which fan is suitable for the World 5000 16R boiler?

Fan KVG-16D (world-5000 13R-20R) is suitable for you.

Error code 95, nothing helps, the computer unit may fail?

Failure is possible. We recommend that you first check the contact where the black wire is screwed onto the boiler body. You also need to pull the terminal off the level sensor and touch it to this screw that secures the black wire. If the error disappears, most likely the coolant level sensor itself has failed.

The Kiturami world-2000 boiler was in operation and stopped working normally, i.e. It takes a very long time to heat up the batteries. What can be wrong?

You may have salt deposits or rust in your main heat exchanger (the result of frequent water replenishment or an open make-up tap), which do not allow the heat exchanger to fully heat up.

When the Kiturami 3000 boiler is operating for heating, error 04 first appears, and then error 96 appears, and it’s as if water hammers are occurring in the system. A little time passes, the unit cools down and operates as before. This mostly happens at night, but also happens during the day.

Tell me what to check?

The coolant movement is probably disrupted. It is necessary to check the internal filter installed in front of the pump. Also external filters installed upstream of the boiler, if available. We recommend adjusting the control unit to prevent boiling in the heat exchanger.

Double-circuit boiler world-2000 deluxe. Recently, the heating switches on spontaneously and displays error 04. Please tell me what is causing this?

Error code 04 – temperature sensor malfunction. There may also be a problem with the plug connection.

Do you need to change the remote control or control unit if all the lights on the control panel blink or go out?

The control unit needs repair. It is also necessary to check the power transformer (located on the right wall inside the device).

The viewing window is blue. Therefore, the true color of the flame must be looked at in the crack between the flame sensor and the burner body (the sensor is not inserted into the hole tightly - that’s what you can see in the crack). It would be good to wipe the sensor with a cloth moistened with any solvent. Try adjusting the opening of the air damper - set it to 5-6 notches. And also try to start the unit by covering the air intake with your hand (before the moment of ignition) (after starting, open it). If the boiler starts and operates stably, set the coolant temperature to 75-80C. Let the chimney warm up and the condensation will evaporate faster. And one more thing - remove and remove the silencer that is located in front of the chimney connection pipe. As for fuel, I don’t quite understand - did you disconnect the fuel line before the standard filter, after the filter (in front of the standard pump), or after the standard pump? It seems that you either have air in the standard pump, or the standard pump is not working.

The diesel Kiturami does not start for some unknown reason. Maybe the injector needs to be cleaned?

To identify the cause of the lack of ignition, diagnostics of the device is necessary.

In a boiler, the fan motor starts to blow only after you hit its body or push the shaft with your hand. The unit is old, but the bearings have recently been lubricated. What else should I do?

If it is not possible to start the engine without mechanical assistance from the outside, then there may be two reasons for this. Poor contact. Over time, the engine wears out, and the armature clings to the stator. In addition, the motor winding and input voltage should be checked. In practice, electric motors in gas models are replaced after 5-6 years of operation.

We installed the Kiturami KSO-50 unit, but we cannot make the first start.

Shows the error “No fuel”, although the fuel is fine.

How to reset the error?

A rumbling sound during startup may indicate problems with either the burner or the turbulator. If the noise continued while the coolant was heating, this would indicate the deposition of mineral salts and clogging of the heat exchanger. The turbulator may have burned out or may have been inserted incorrectly and vibrate. It must be removed and cleaned of carbon deposits.

The diesel boiler starts only with the damper on the front of the housing closed. What does this mean and how to fix it?

By all indications, the firebox is clogged with soot. It is necessary to clean the firebox and adjust the burner.

For the Kiturami 21 diesel boiler, I want to install a tank with diesel fuel in the yard near the boiler room. Should I put an additional filter on the fuel line?

For units of this brand, the location of the fuel container outdoors is not provided. The point is that when low temperatures The diesel fuel thickens, and the fuel pump, made of plastic, cannot cope with the load and quickly fails. Given the weak pump, it is necessary to install the tank next to the boiler in the room. In this case, there should be a fuel intake valve at the bottom of the tank, to which the pump is connected. According to the diagram, the connection is made from the bottom of the tank so that the fuel is supported.

An additional filter also puts extra stress on the pump, which leads to premature wear.

The diesel unit is difficult to start. Fuel is poured into a canister, into which a hose is lowered from above. I tried to adjust the diesel fuel supply, but it got even worse. Maybe the pump is faulty?

For proper repairs, the equipment and fuel lines must be thoroughly inspected. First of all, for this brand, the hose must be connected to the container from below. Avoid fuel pump failure, filter contamination, and low fuel pressure.

World 5000 has entered error 95 and I can't do anything about it. I already drained all the water and did a restart. The water pressure is normal, but the error persists. What is the reason?

There are a number of malfunctions in the operation of the boiler that cause this error to appear.

At the same time, the coolant level in the heating system remains normal, and nothing needs to be added.

The Kiturami Turbo 30 R began to smoke a lot: very black smoke comes out of the chimney.

Fuel consumption became enormous - almost a ton of diesel fuel burned in three months.

Need to do something. Your boiler needs cleaning and adjustment of the burner using a gas analyzer. As you know, 2 mm of soot on the heat exchanger reduces the boiler efficiency by 15%. I want it in diesel

floor boiler Kiturami Turbo 21 change the nozzle to a smaller one in order to save money. Mine requires 3 liters of diesel fuel per hour, and the nozzle from Turbo 17 requires a liter less. This can be done? Simply changing the injector to a smaller one will not solve your problem. It will be necessary to reconfigure the pump to a different pressure, and the savings will be insignificant. More

rational decision – this is the burner setting. Heating a home in winter is a top priority for every homeowner today. This issue is most relevant for owners of suburban housing. And although modern

gas boilers

are the most advanced, but for many people they are inaccessible due to the constant increase in the price of this type of fuel. Therefore, a large number of consumers choose other alternative options, one of which is the Kiturami diesel boiler. Although they are not new on the market, they have not lost their popularity at all. They are able to provide high-quality heating in the house. Today Kiturami is a well-known South Korean concern, one of the most large manufacturers heating equipment. The boilers of this company have been repeatedly awarded diplomas for reliability and technical perfection, and due to the presence of certificates that meet all

international standards

, Kiturami diesel heating boiler is exported to almost all countries. What is special about heating equipment from Kiturami? The Kiturami concern produces different types heating equipment, which includes biofuel and

gas installations

. But it was Kiturami’s diesel heating equipment that brought the concern such great fame and a high rating. The name diesel itself speaks about the type of fuel on which it runs. Rice. 1 The most popular model in the line of this manufacturer is the Kiturami Turbo 17 diesel boiler, the purpose of which is hot water supply and heating of industrial and residential premises. Boilers from the manufacturer Kiturami are very convenient for use in country houses does not occur every day, and heating will only be required when the owners are present there. In addition, with proper operation, repairs of such equipment are very rarely necessary.

The main advantages of Kiturami diesel heating equipment include:

  • The Kiturami diesel boiler is easy to use. The control panel allows you to set any control function. The operation of Kiturami using coolant and room temperature is regulated by a thermostat built into the remote control. The boilers are independent of the size of the chimney and the presence of draft due to their turbo-inflating effect, which forces exhaust gases into the chimney;
  • diesel Kiturami is highly economical. Thanks to the aerodynamic flow in the combustion chamber, maximum efficiency in the amount of fuel consumed is achieved;
  • setting up the equipment is absolutely simple, and you can do it yourself;
  • all year round The house has hot water supply. Kiturami brand boilers are also used when the room is not heated;
  • The Kiturami diesel boiler has a self-diagnosis system, which on the display informs about its operation and any malfunctions that have arisen, showing the real state of the system. If you constantly monitor the display readings, the need for repairs will be minimal.

Features of Kiturami in operation

Diesel heating unit, represented by the Kiturami concern, differs significantly from other brands in its characteristics, both in the method of maintenance and the need for repairs. Only high alloy steel is used to produce the heat exchanger.


Rice. 2

Kiturami brand boilers are made of copper, which is highly resistant to water. If we talk about price, then in comparison with stainless steel, copper is much cheaper, and, accordingly, a diesel boiler costs accordingly. In addition, copper significantly increases the heat resistance of equipment.

The quality of work of Kiturami Turbo depends on how correctly the containers in which the fuel is stored are placed. Here it is necessary to correctly place the tank and position it on three surfaces. It is imperative to ensure that a drain is provided in the sediment tank. The Turbo reservoir should be cleaned regularly and sediment should be drained, and fuel should be filled into the diesel engine only in purified form. Such treatment contributes uninterrupted operation, and there will be no need for repairs.

When filling a Kiturami diesel boiler with fuel, the instructions say that you need to wait half an hour until it settles. Only after this can the Turbo diesel boiler be started and the required modes adjusted. It is also advisable to use a stabilizer to avoid repairs from sudden changes in voltage in the network. It will ensure stable operation control unit, and will also protect the heating unit from premature repairs.

In order for the Kiturami diesel heating boiler to operate smoothly during operation, the following is necessary:

  • the boiler adjustment must be carried out competently and correctly, then the need for repairs will be minimal;
  • a diesel boiler requires systematic implementation mechanical cleaning in order to protect against premature repairs;
  • Turbo should be regularly monitored to check the operation of all its connections and components for leaks;
  • The performance of the equipment must be checked regularly so that there is no need to repair Kiturami diesel boilers prematurely.

Equipment installation and connection

All the requirements for connecting Kiturami are absolutely not difficult to fulfill on your own. You can install a Kiturami diesel boiler without the help of specialists; all you need to do is carefully study the diagram and recommendations of the manufacturer itself. But at the same time, there are many operations that require the presence of qualified craftsmen in order to subsequently avoid repairs.

For those people who have to assemble heating equipment Kiturami diesel boilers for the first time, the instructions and installation diagram will serve as clear example carrying out such work. It is very important that the Kiturami Turbo connection is made using electrical diagram boiler and all recommendations when connecting to the electrical network were strictly followed.

Anyone who is not sure that they can independently carry out all the work efficiently, on which setting up a Kiturami diesel boiler directly depends, then it is best to involve specialists, and thus avoid possible errors and premature repairs.

The Kiturami diesel boiler requires an extremely precise procedure and principle for its installation, since an incorrect connection most often causes equipment malfunction and there is a need to carry out expensive repairs of Kiturami diesel boilers.

Description of Kiturami malfunctions and repairs

The Kiturami diesel boiler belongs to the economy version and has a fairly long service life. But there are also situations when boilers fail prematurely. The reason for the need to repair Kiturami is their untimely maintenance or the use of low quality fuel.

You can carry out simple repairs of Turbo boilers yourself, but it is more rational to contact service organizations in case of malfunctions.

Rice. 3 Installed Kiturami boiler

Below are the main error codes that the Kiturami Turbo 17 diesel boiler most often experiences:

  • when the lights flash “01”, “02” or “03” on the display, it means there are problems in the flame detector and ignition does not occur. In this case, the Turbo boiler should be restarted according to the instructions;
  • error “04” indicates that the water temperature sensor is faulty in the Kiturami heating system, and repair in this case becomes inevitable;
  • error "08" warns that the route between the boiler and temperature sensor very long or the wire has broken somewhere. Repairs will be required to identify the immediate cause of the operational failure;
  • error “95” means the pressure in the heating circuit is too low. The Turbo boiler needs to be energized and the entire heating system inspected for possible leaks;
  • error “96” - the mechanism that protects the Turbo system from overheating has activated;
  • error “98” - indicates that there is a lack of fuel in the supply line.

Of all the errors described above, “01” blinks most often on the display, but this does not pose a great danger to the operation of the equipment. The Kiturami Turbo 17 diesel boiler is characterized by maximum efficiency. Thanks to the control panel, boiler control functionality is achieved and room heating is possible in any temperature conditions.

In Turbo it is possible to regulate temperature parameters step by step from 45 to 75°C. All information about the operation of the diesel Kiturami Turbo is displayed on the thermostat screen by a self-diagnosis mechanism.

Most often, the Kiturami diesel boiler produces error 01. This happens when there is no stable ignition in the Turbo.

The reasons may be as follows:

  • when the screw jams, which serves as a fuel level limiter. The repair consists of replacing the locking element or checking the injection motor;
  • when the injection motor fails. It is necessary to check the working condition of the Kiturami motor. If the motor is faulty, then the repair consists of replacing it with a new one;
  • when there is not enough incoming fuel, then the level in the tank should be checked; repairs in this case will not be necessary;
  • when a foreign object accidentally ends up in the screw gate, it must be removed during the repair process;
  • when the photosensor fails, the Turbo repair consists of checking this element for its functionality.

When error code “01” periodically appears on the display, in such cases it is necessary to seek help from the appropriate specialists in order to avoid major expensive repairs.

Carrying out regular maintenance and repairs of Kiturami is a guarantee that Turbo boilers will operate efficiently and reliably. If irreparable damage occurs to a diesel boiler during the warranty period, it will be repaired without the need to pay for such work.

The Kiturami Turbo diesel boiler has excellent characteristics, but you must always remember that non-compliance established scheme installation, proper configuration and basic handling rules in many cases ends in total repair. When all requirements for use and operation are met modern technologies production of heating equipment Kiturami guarantees each user stable operation of the boiler without the need for repairs and a long service life.